ENERGINIE SAI/UPS RACK 3000VA LCD
SAI/UPS - SAI 3.000VA - ENERGENIE EG-UPSRACK-13 - ENERGINIE SAI/UPS RACK 3000VA LCD
EG-UPSRACK-13
Rack UPS, 3000 VA, black
ULTIMATE DEFENCE
Protects important data from power cuts
Protects valuable equipment
Protects users
Automatic output voltage regulation (AVR)
Rack 3.4U metal case
USB control interface
LCD display
Short circuit protection
Compatible with power generators of any brand
Surge, spike and lightning protection
Audible and visual alarms
Overcharge and overdischarge protection
Especificaciones
UPS type: line interactive, pure sine wave
Input: 220V AC ± 25%, 50Hz / 60Hz ± 10%
Output: 220V AC ± 10%, 50Hz / 60Hz ± 0.5% (on battery)
Output power factor: 0.8
Inverter output efficiency (resistive load): 85%, any load type is allowed
Switching time: no more than 10 ms (typically 6 ms)
Backup time: 8...20 mins (depends on the load)
Battery: 151 x 65 x 95 mm, sealed lead-acid 12 V / 9 Ah / 2.3 kg x 4 pcs
Charge time: up to 12 hours
Sockets: input IEC C14, outputs: Schuko EU type x 1 pc, IEC C13 x 6 pcs
Operating conditions: 0°C~40°C, at humidity 10~90%RH non condensing
Noise: < 45 dB (at 1 meter distance)
Power: 3000 VA (1800 W)
Dimensions: 440 x 410 x 132 mm
Product weight: 28.1 kg
Cold-start function
System requirements
In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work.
Rack UPS, 3000 VA, black
ULTIMATE DEFENCE
Protects important data from power cuts
Protects valuable equipment
Protects users
Automatic output voltage regulation (AVR)
Rack 3.4U metal case
USB control interface
LCD display
Short circuit protection
Compatible with power generators of any brand
Surge, spike and lightning protection
Audible and visual alarms
Overcharge and overdischarge protection
Especificaciones
UPS type: line interactive, pure sine wave
Input: 220V AC ± 25%, 50Hz / 60Hz ± 10%
Output: 220V AC ± 10%, 50Hz / 60Hz ± 0.5% (on battery)
Output power factor: 0.8
Inverter output efficiency (resistive load): 85%, any load type is allowed
Switching time: no more than 10 ms (typically 6 ms)
Backup time: 8...20 mins (depends on the load)
Battery: 151 x 65 x 95 mm, sealed lead-acid 12 V / 9 Ah / 2.3 kg x 4 pcs
Charge time: up to 12 hours
Sockets: input IEC C14, outputs: Schuko EU type x 1 pc, IEC C13 x 6 pcs
Operating conditions: 0°C~40°C, at humidity 10~90%RH non condensing
Noise: < 45 dB (at 1 meter distance)
Power: 3000 VA (1800 W)
Dimensions: 440 x 410 x 132 mm
Product weight: 28.1 kg
Cold-start function
System requirements
In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work.